ELECTRATILE ESD FLOOR TILES

ESD Floor Tile Specifications

12" X 12", 1/8 inch thick, 45 square feet to a carton

Carton Dimensions: 13 X 13 X 6 Inches

Weight per Carton: 56 pounds each.

PRODUCT OVERVIEW: ElectraTile ESD flooring features a high rating for dimensional stability and compressive strength and is supplied in the static conductive range of <1.0E06 for the fastest, most complete charge decay of any esd vinyl tile in the industry. ElectraTile's outstanding micro-finish provides a clean high tech appearance while it's superior total composition (devoid of cheap fillers and clay binders) provides unparalleled wear resistance with a > 20 year life expectancy and a Lifetime Warranty on Electrical Conductivity. ElectraTile ESD Tile, THE choice for controlling esd in clean rooms, electronic manufacturing, computer rooms, repair facilities or anywhere static control is a requirement.

ITEM Standard test Method ASTM Spec ESD Static Conductive Tile

ELECTRICAL / ELECTROSTATIC PROPERTIES

Electrical Resistance
-Surface to Surface

-Surface to Ground
ESD S 7.1 (100V / 10V)
ASTM F-150 (100V / 10V)
 
>2.5 X 104~<106Ω
 
2.5E04 <1.0E06
 
>2.5 X 104
>2.5 X 104 ~ <1.0 X 10 6 Ω
Electrostatic Propensity
AATCC 134-19
* In recommended Non Conductive Footwear
< .4kV
Electrostatic Propensity

AATCC 134-19 (supplemental testing)

In ESD conductive shoes

< 20 volts

Electrostatic Propensity ANSI ESD S20.20-2014, 97.2

<100 Volts

Passes at < 100 V (< 10 volts common)

Static Decay, Method 4046 at 15% rH

ASTM F-101C

 < 0.5 sec
 <0.01 sec
Electrical Resistance D.O.D. HDBK236A, Section 40.1.2

N/A

Meets recommended guidelines for ESD Devices, Class 1

 OTHER PROPERTIES

CEN Classification DIN EN 685  
Class 34 + 43
Composition of Material ASTM F 1700

 Certificate of Compliance

Homogeneous
Thickness ASTM F 386, DIN EN 428
as specified ±0.005 in. (.125)
.125
Nominal Sizes ASTM F 536, DIN EN 427
±0.016 in./lin. Ft (0.4mm/304.8 mm)
12" x 12", 24" x 24"
Residual Indentation ASTM F1914
DIN EN 433
average less than 8%,
max. single reading 10%
< 7%

Static Load

ASTM F-970-07

2,500 PSI

2.500 PSI

Flexibility ASTM F 137
no crack or break
No crack or break
Dimensional Stability ASTM Fed. Std. No. 501a
Method 6211, DIN EN 434
<0.020"/ft (0.51 mm/304.8 mm)
<0.015"/ft
Resistance to Certain Chemicals ASTM F 925
DIN EN 423
No more than a slight change in surface dulling, surface attack or staining
no more than a slight change in surface dulling, surface attack, or staining
Resistance to Heat ASTM F 1514
∆<8 ave., max
<∆E=2.0
Resistance to Light ASTM F 1515
∆E<8 ave., max
<∆E=6.0
Static Load Limit Modified ASTM F 970-00
-
>2,500 psi
Smoke Density ASTM E 662
<450
<450
Flame Spread ASTM E 84, NFPA 225
<75
<75
Fire Resistance DIN 4102  
B1
Critical Radiant Flux ASTM E 648, NFPA 253

 Pass

>1.08 W/cm2(class I Interior Floor Finish, NFPA Life Safety code 101)
 Abrasion Resistance ASTM D 1044,
CS-10-F Wheel,
500Gm Weight

 -

Cycle
10,000
% Gauge Loss
1.60
 Resistance to Wear DIN EN 660-1

 -

M
Effect of Castor Chair DIN En 425

 -

No Damage
 Color Fastness ISO 105 B02

 -

At least 6
Standard for Health Care Faculties NFPA 99

 -

Conforms to the requirements of NFPA 99 in effect at the time of installation
Fulfils product requirements DIN EN 649

 -

yes
Underwriters Laboratories UL 779

 -

Meets UL Standard

WARRANTY

Free from defects in Workmanship and materials*    
Lifetime
Conductivity*  
 
Lifetime

ElectraTile Series Green Indoor Air Certification Indoor Air Qualification Icon

Reference Standard: California Department of Health CDPH/EHLB/Standard Method Version 1.1, 2010, (Emission testing method for CA Specification 01350)

 

• CALGreen, CA Code of Regulations Title 24, Part II, 2010, Sections 4.504.4/5.504.4.6: Resilient Flooring Systems

• ANSI/ASHRAE/USGBC/IES Standard 189.1-2009, Section 8.4.2.3: Floor Covering Materials

• USGBC LEED CI, NC, Schools, 2009, IEQ Credit 4.3: LEM - Flooring Systems

• USGBC LEED for Healthcare, 2009 (Feb 2011), IEQ Credit 4: LEM, Group 3 - Flooring

• Collaborative for High Performance Schools (CHPS) rating system, 2009 Criteria. EQ2.2.3: Flooring Systems

• Green Guide for Healthcare, V2.2, 2007, EQ Credit 4.3: LEM - Flooring Systems

PN: ET- White Ice 6101, ET - Ice Blue 6001, ET-604, ET-605, ET-6091, ET-6061

 

United Static Control Products Inc

Approved: SRC

 

DOCUMENT NUMBER

SRC10112B

 

DATE:

11.12.20